MW.USERBUFFER#

Description

MW.USERBUFFER allows the user 32 memory values that the user can interact with over telnet, fieldbus and MechaWare.

These values are often used to allow MechaWare to save values from one sample to another, or to provide a simple user interface and often aids in debugging.

There are 32 memory values and the index range is 0 – 31.

 


  • The user buffer values can be used for anything but will never have units associated with them, and will always be double precision value.

Example

Set Value

-->MW.USERBUFFER 10 12.3		

Read Value

-->MW.USERBUFFER 10	
12.300000

Versions

Action

Version Notes
Implemented 02-00-00-000

General Information

Type Read/Write
Units N/A
Range -9223372036854775808.0 to 9223372036854775808.0
Default Value 0
Data Type Double
Stored in Non-Volatile Memory Yes

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

MW.USERBUFFER 0

30e5h

01h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 1

30e5h

02h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 2

30e5h

03h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 3

30e5h

04h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 4

30e5h

05h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 5

30e5h

06h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 6

30e5h

07h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 7

30e5h

08h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 8

30e5h

09h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 9

30e5h

0ah

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 10

30e5h

0bh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 11

30e5h

0ch

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 12

30e5h

0dh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 13

30e5h

0eh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 14

30e5h

0fh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 15

30e5h

10h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 16

30e5h

11h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 17

30e5h

12h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 18

30e5h

13h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 19

30e5h

14h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 20

30e5h

15h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 21

30e5h

16h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 22

30e5h

17h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 23

30e5h

18h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 24

30e5h

19h

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 25

30e5h

1ah

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 26

30e5h

1bh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 27

30e5h

1ch

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 28

30e5h

1dh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 29

30e5h

1eh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 30

30e5h

1fh

Signed32

-

1000:1

Read/Write

No

MW.USERBUFFER 31

30e5h

20h

Signed32

-

1000:1

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

2800

1

2800 (0xaf0)

MW.USERBUFFER

Signed32[32]

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

MW.USERBUFFER

2800

Float[32]

Read/Write

-